Jul 30, 2008 - Currently, the nut-hal-drivers package only supports USB-based UPS's. 2009 at 6:27 PM. I have a mustek powermust 600 and I am trying to connect it by USB. Service nut-server stop sleep 10.

] 63, D-41468 Neuss Uninterrupted power supply line interactive 600 VA / 360 W 115 / 230 VAC 80 - 145VAC / 160 - 290VAC 115 / 230 VAC ± 10% 50 or 60 Hz ± 1 Hz Modified sine wave Maintenance-free rechargeable battery 10 minutes 3-8 hours to 90% after complete discharge.

• USER’S MANUAL PowerMust 400/600/1000 Offline Uninterruptible Power System 28-2MAXPO00201. • IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerMust 400 Offline, PowerMust 600 Offline, and PowerMust 1000 Offline that should be followed during installation and maintenance of the UPS and batteries. • Safety – CAUTION! This product is specially designed for PCs and it is not recommended for use in any life-supporting system and other specific important equipment. Download spiderman 3 jar 320x240. CAUTION: Risk of electric shock, do not remove cover.

No user serviceable parts inside. Refer servicing to qualified service personnel. • battery terminals. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type of sealed lead-acid battery. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.

• System Description Front panel: 1. Power Switch 3. Fault LED: Red flashing 2. UPS status Indicator – AC Mode: Green lighting Battery Mode: Green flashing 400/600 1000 Back Panel 1. Output receptacles 3.

Modem/Phone Line Surge 2. Fuse (Protection Function) 4. • Installation and operation 1.

Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Computer Connection Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. Modem/Phone Line Connection Plug incoming Modem/Phone line into the “In” socket at the back of the UPS. Trouble Shooting Symptom Possible Cause Remedy No LED display 1.

Manual

Battery Weak 1. Re-charge battery up to 8 on the front hours. Battery defect. Replace with the same type of battery. Power switch is not 3.

Specification PowerMust 400 PowerMust 600 PowerMust MODEL Offline Offline 1000 Offline CAPACITY VA/W 400VA/200W 600VA/300W 1000VA/600W INPUT Voltage 110/120VAC 220/230/240VAC Voltage Range 90-145VAC / 170-280VAC OUTPUT Voltage 110/120VAC 220/230/240VAC Voltage Regulation ±10% (Batt. Mode) Frequency 50Hz or 60Hz Frequency Regulation +/-1 Hz (Batt. • PROTECTION Full Protection Discharge, overcharge, overload*(only for 1000VA) Dimension, DXWXH 213x75x185 281.4x84x240.5 PHYSICAL (mm) Net Weight (kgs) Operating Environment 0- 40° C, 0-90% relative humidity (non-condensing) ENVIRONMENT Noise Level Less than 45dB.